Digital Glass Body ORP Electrode for General Purpose
HI36180
Description
The HI36180 is a glass body, double junction, refillable ORP electrode with a built-in temperature sensor for temperature compensated measurements. This electrode has a single ceramic junction and the ORP sensing pin is made with platinum.The HI36180 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. This design consideration is ideal for laboratories and general purpose ORP measurements.
•  3.5 mm Connector
•  Built-In Microchip
•  Platinum Sensing Pin
  The HI36180 features a platinum sensing pin, glass body, double junction reference and is refillable with 3.5M KCl.
Built-in Microchip
•  The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used.
•  This information is automatically retrieved by edge® once the electrode is plugged in.
•  The ability to transfer information allows for hot swapping of probes without having to recalibrate.
•  All pH measurements are performed within the electrode and transferred digitally to the meter.
•  This overcomes any noise issues associated with the traditional high impedance analog measuring system.
•  Electrical noise can be generated from a built in temperature sensor and while working in a humid environment.
  Platinum Sensing Pin
•  The HI36180 ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself.
•  It must also have the proper surface characteristics to promote rapid electron exchange, a property known as high exchange current density.
•  Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors.
•  The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient.
•  The platinum sensor signal is carried through the electrode body, and together with the reference signal is conducted to the measurement meter.
  Glass Body
•  The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned.
•  The glass body also allow for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent.
•  The faster the equilibrium the steadier the reference potential.
  Double Junction Reference
•  A double junction electrode has an internal compartment surrounding the reference wire.
•  Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free.
•  The double junction design means that virtually no silver from the electrode enters the sample.
•  This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.
  Refillable
•  The HI36180 is a refillable probe. Since it is a double junction ORP electrode the fill solution is the HI7082 3.5M KCl.
•  If using a refillable ORP electrode, the fill cap should be removed prior to measurement.
•  Removing the cap creates positive head pressure in the reference cell allowing for higher flow rate of electrolyte through the outer junction.
•  A higher flow rate will result in a faster and more stable reading.
  Built-In Temperature Sensor
•  HI36180 features a built-in thermistor temperature sensor that is in the tip of the indicating pH electrode.
•  A thermistor temperature sensor provides for a high accuracy temperature reading and should be as close as possible to the indicating pH electrode in
order to compensate for the effect that temperature has on the membrane potential.
•  By having an accurate reading it is possible to provide an accurate temperature compensated reading.
SPECIFICATIONS
| Range : | ORP: ±2000 mV | 
|---|---|
| Body : | Glass | 
| Reference : | double, Ag/AgCl | 
| Junction/Flow Rate : | ceramic, single/ 15-20 μL/h | 
| Electrolyte : | 3.5M KCl | 
| Max. Pressure : | 0.1 bar | 
| Tip Shape : | platinum pin | 
| Diameter : | 12 mm | 
| Body Length/Overall Length : | 120 mm / 175.5 mm | 
| Matching Pin : | no | 
| Amplifier : | yes | 
| Digital : | yes | 
| Recommended Operating Temperature : | -5 to 100°C (23 to 212°F) | 
| Temperature Sensor : | Yes | 
| Cable : | 1 m (3.3’) | 
| Connection : | 3.5 mm connector | 
| Applications : | laboratory general purpose | 
| Warranty : | 6 months | 
Order now
To make your order, please contact us at info@polyscientific.com.my or call us at +6 06 3350 690
 
			
					

 
	
		 
	
		 
	
		 
	
		 
	
		